Quantcast
Channel: Power management forum - Recent Threads
Viewing all articles
Browse latest Browse all 35901

BQ34110EVM-796: BQ34110EVM-796 by the BQSTUDIO write the bq34110 dataflash fail

$
0
0

Part Number:BQ34110EVM-796

Hi ALL:

 just  now I find out a problem that the BQ34110-EVM796 can't write the bq34110 dataflash correctly.

I write the BQ34110 the Number of the Series cell dataflash,the write operation step:

Change the  Number of the Series cell to 0x08 and the BQ34110 default is 0x01
Use the Advanced Comm section to write the data flash.
Start Register 3E, Bytes to Write 55 41 (data flash address)
Start Register 40, Byte to Write 08 (new data)
Start Register 60, Byte to Write 61 (checksum)
Start Register 61, Byte to Write 05 (length of data written)

after this operation and I want to read the Number of the Series cell dataflash but the value is still 0x01