Quantcast
Channel: Power management forum - Recent Threads
Viewing all articles
Browse latest Browse all 35901

BQ40Z50-R2: bqStudio ASCD settings

$
0
0

Part Number:BQ40Z50-R2

Hi,

I've question about bqStudio functionality:

When I try to set the current limits in Short Circuit in Discharge (ASCD) protection, I see in manual, that there are 3 settings I need, which I found in Table A-8, Table A-10, and Table A-12 (Vsense value threshold, and two delay thresholds).
When I open GUI, I See only two fields. (please, see attached image)

Questions:

1.1) Do I understand correctly, that first 4 bits - it's time delay threshold, second 4 bits - Vsense threshold? Whether first bit is dummy bit, next 4 bits - time delay, and last 3 bits - Vsense?
In example above - do ASCD settings mean ([SCDDx2] = 1) : Vsense= -200mV; Delay1 = 854us, Delay2 = 854us?

1.2) What happens, if I write 0xFF - because, I see that Register can accept max values up to 0xFF?

2) Where can I read the functional meaning of Delay1 and Delay2? - haven't found this info in manual...

3) What is the difference between "Counter Dec Delay", "Reset" and "Recovery" params?