Hi,
Chip(BQ78PL116)
I received the batteries after sales service, the flag of DC and DC flag is set to 1.
This occurs because the standby power consumption of the product is below the Transition to Idle Current.
The battery is fully charged (CC is set).
The standby mode of the product, slowly draining the battery (DC is set).
The RSOC is 0%.
The flag "Charge Completion" does not turn off and the battery is completely discharged.
The battery is unusable! It seems that this is a bug.
Did you do an update?
Is what I omitted the configuration of a parameter?
Thanks