Dear Sirs!
Currently I am working with the evaluation module BQ34Z100EVM and EV2300.
IFR 32650, 12V, 20Ah, LiFePO4, 3-cell battery pack of OPTIMUM BATTERY CO., LTD manufacture is applied. The board is set and calibrated correctly. According to SLUA334B the Chem ID must be determined before the microchip learning. To do this, I took off voltage, current and temperature data during the battery charge and discharge. To calculate the Chem ID I used only discharge data. Then I substituted the data in the following Mathcad files: chemselect_cont2.mcd, chemselect_rev32.xmcd, chemselect_cont_rev35_mcd11.xmcd, but did not manage to get the Chem ID values. Probably, it is necessary to create a new Chem ID for this battery.
What should I do in this situation? Can I create a new Chem ID or this must be done only by your specialists?
With Best Regards,
Sergey