Part Number:BQ27441-G1
Hello! I have an BQ27441-G1A and 1000mAh and 950mAh batteries (max charge voltage 4.2V).
So with default Design Capacity (1340mAh), Design Energy, Terminate Voltage, and Taper Rate the battery 1000 mAh worked for about 35 hours in some design. If replace it with 950 mAh, then the operation time is reduced to 22 hours. I tried to implement a flowchart from SLUUAP7 (changed typical values, to a 950mAh battery) : as before reconfiguration 1000 mAh battery works for about 35 hours, and 950 mAh - about 22 ... What could be the problem? The flowchart precisely configures the microchip (the checksum is updated).