[BQ34Z100PW] Remove Battery after IT Enable&Seal

1. run optimize cycle ->  check Qmax updated, R table updated, Update status:06

2. change *.gg file.. -> Update Status=02, cycle count =0.

3. Connect BQ34Z100 to Battery -> Sellect Cell ID -> Write *.gg -> Calibration -> IT Enable(Send 0x0021) -> Seal(Send 0x0020)

in this condition... status bits FAS, SS, VOK, QEN is set

4. remove battery from BQ34Z100 and reconnect battery to BQ34Z100.

Status bit RUP_DIS is set, and VOK is Cleared, QEN is Set.

--------------------------------------------------

"RUP_DIS=set" in product condition... is it right??

or never remove battery from BQ34Z100 after IT Enable???

if i remove battery from BQ34Z100. need to send 0x0021 when i reconnect battery to BQ34Z100??