BQ24650: STAT1 and STAT2 cycle blink when battery is fully charged

$
0
0

Part Number:BQ24650

Hi team,

Within our application, the bq24650 blinks periodically STAT1 & 2 with the following cycle steps :

STEP numberSTAT1STAT2Supposed charge state
1ONOFFCharge in progress
2OFFONCharge complete
3ONONFault (?)
4--Go back to step 1

For a better understanding of the situation and the time elapsed between each steps, please take a look at this video

The cycle period is slower when current is lower.

Nominal battery voltage is 12V and lead acid. During  the video, the voltage is around 13.3V so we assuming battery is fully charged.

Our question : Is it a normal situation ? Because we assume when battery charging is completed, charge complete state should be idle and stable.

Regards,

Maxime.