Hello Everyone,
I am using BQ34Z950 with 4s3p battery pack.
Single cell voltage 4.2v with capacity 2200mAh.
I have observed a gas gauging problem, when battery discharged till 14.00v and continuously charging battery pack for 2-3 hours battery voltage shown is 15.6V but battery percentage is 93%. When i reset using 0x0041 command, battery percentage get updated to 62%.
I am unable to understand this condition. How can i resolve this issue?
And also what does Max error indicates?