How can change update status bit of bq34z100?

$
0
0

 hi. I saw how to do pack gauging about bq34z100 at this forums.

http://e2e.ti.com/support/power_management/battery_management/f/180/t/253751.aspx (last text)

However, update status was not change  to '06', despite many attempts.

 

This picture is our software screen of bq34z100. 

I tried to discharge at C/5 rate after relaxing for 2hours next full Charging. After 2 attempts of charging and discharging, update status was not change '04' to '06'.

Update status was never changed '04' to the other number.

I guess the problem is VOK bit.

I checked that VOK bit is always LOW during Discharging but VOK bit is HIGH bit at charging time. 

I know that VOK bit must HIGH during a cycle time.

How can I change update status from '04' to '06'?

I have attached a test file.

Regards

KIM