Quantcast
Viewing all articles
Browse latest Browse all 35901

BQ78350 charge disable register

Hi,

We are trying to set up the protection on the BQ78350 to monitor/control battery charging.

In the Technical Reference Manual SLUUAN7 Rev. A section 5.5, the conditions to disable charging are confusing.

How can the UTC (under temperature during charge) and OTC (over temperature during charge) be set at the same time?

Second, if any of these two bits are set, according to the documentation, charging is disabled through the OperationStatus()[XCHG] bit.

Is this a typo or is my understanding incorrect?

Thanks


Viewing all articles
Browse latest Browse all 35901

Trending Articles