[BQ34Z100] Heating problem

$
0
0

Part : BQ34Z100

Schematic : Similar Figure 7 @ datasheet

Problem : BQ34Z100 Self Heating & REG25(Regulator output) voltage = 3.3V

Item Count : Total=16EA , Self Heating=6EA       =>  6/16=37%

C1, C2, C8 is shortest path to BQ34Z100.

same problem at below link.

http://e2e.ti.com/support/power_management/battery_management/f/180/t/329819.aspx?pi300607=2

normally it operate good...(No Heating & REG25=2.5v)

but after long time aging.... REG25 output voltage=3.3V & heating..  and not recover..

remove battery and reconnecting... it is only way to recover.

---------------------------------------------------------------------------------------

is there overvoltage protection at internal regulator output???

(I guess internal overvoltage protection part  make heating)

internal regulator only operate for external Thermister(RT1) and VEN??

(can i use BQ34Z100 without internal Regulator(Broken Pin number 6, 7) and external LDO 2.5v))

adding resistor between BAT+ to REGIN.  it can solve problem??

i want to know internal block Diagram of BQ34Z100.....