Part Number:BQ24610
Hello
I am taehwan.
I contacted early because of similar problem.
Let me explain about setting of BQ24610
Vin 15V
Vbat 13.05
Fast charge current: Max 1.5A
Termination current: 0.145A
AC input current: 4A
recently, I checked the blinking STAT1 after finishing charge.
on detailed, when the charge current reach to termination current first time ,then stat2 is on and stat1 is off.
but after fulled battery insert on PCB again , then I saw blinking stat1 after a few minute.
this phenomenon is abnormal I think.
Would you let me know why a problem occur?
Thank you
best regards
Taehwan Choi