BQ34z110 Optimization cycle, OCVTAKEN after charging won't set

$
0
0

Hi,

I am currently running a optimization cycle with a bq34z110 in combination with a 40Ah (current scale 1/2) sealed lead acid battery.

-I started with a fully loaded and relaxed battery,
-Send IT enable
-After 20min OCVTAKEN was set
-Discharged at c/8 rate
-Made a few extra discharge cycles at the end to overcome the voltage bounce problem
-OCVTAKEN was set after a really long time
-Charged the battery till current < 200mA
-And the battery is currently relaxing 

The battery has been relaxing(step 6) for almost 24 hours and counting and still no OCVTAKEN.

Can someone tell me what is wrong please?

I also have been searching this forum for hours to find some kind of summary of all the things that should be taken into account when running a optimization cycle,
But with no results, I also find a lot of contradictions in different posts and pdf files from TI...

The logging and settings are attached.
Note: I have changed the extension to txt because the original weren't valid for upload  (.log and .gg)

Thanks in advance

Kind regards,
Kris