Hi,
We are currently developing using the BQ78350 and we are trying to configure the temperature threshold for charge inhibit.
Section 5.6 of the TRM says that the BQ be in a normal status when the temperature is greater than Charge Inhibit/Suspend Low + Hysteresis. The CHGIN bit will be set when the temperature is below Charge Inhibit/Suspend Low threshold.
However, what happens when the temperature is between the threshold + hysteresis and the threshold?
A similar situation applies to the high temperature threshold.
Regards,
Michal