Hey guys I'm pulling data from the following registers when the BQ78350 is in Unsealed mode.
As soon as I sealed the chip which I did by accident I saw that the registers below stopped returning the correct data. I then used the BQ Software to unseal the device and the register reads started coming back correct again.
0x2B - FET Status : 1111111111111111
0x16 - Battery Status Flags: 1111111111111111
0x50 - Safety Alerts: 11111111111111111111111111111111
0x51 - Safety Status: 11111111111111111111111111111111
0x54 - Operating Status: 11111111111111111111111111111111
0x55 - Charging Status: 11111111
0x52 - Permanent Failure Alert: 1111111111111111
0x53 - Permanent Failure Status: 1111111111111111
How do I access this data while the BQ78350 has been switched over to Sealed mode?
Do I have to add x00 to the read code so it request to read from 0x002B, x0016, x0050.........