Hi,

I have a question about fault condition.

In D/S,  9.3.4.1 Overload Protection
 "The maximum duration for the over current through the FET is tCL_PLIM(dly), 162 msec (typical)."

In other words, does this device latch-off without thermal shutdown?
My customer previously tested this feature for TPS2660. However, this device required a thermal shutdown for latch-off.

The TPS26624 was able to operate as customer desired, but I will propose the TPS16630 for the power boards with higher current.

Best regards,