Hello,
I would like to use a BQ34Z100-G1 gas gauge device to monitor a battery supplying a transceiver. The load current varies
considerably i.e, 50uA in sleep, 30mA in receive and 1.5 Amps during transmission. From what I understand from the
datasheet it seems the BQ34Z100-G1 is meant for load currents in excess of 1mA. In addition the transceiver transmission
pulse is 0.5 seconds in duration and occurs randomly. As the integration ADC conversion time is 1 second typically it
seems that it could miss a fast event such as a transmission. Could you advise me if my reasoning is correct and if so
is there any other solution to my problem.
Many thanks
John
↧
Using the BQ34Z100-G1
↧