Quantcast
Channel: Power management forum - Recent Threads
Viewing all articles
Browse latest Browse all 35901

bq34z100-g1 flash write error after setting VOLTSEL bit

$
0
0

Hello,

After I set the VOLTSEL bit and the number of cells to 12 I am not able to write any other settings to flash.

The bqStudio program shows the error: "a read of data written failed comparison".

However when I restore to previous settings (by reprogramming my old golden file - flash), I can change settings as normal. What does change internally in the bq34z100-g1 after setting the VOLTSEL to 1 ?

Additional info of my setup:

I'm using the bq34z100 EVM board with EV2300 I2C communication. On the board I swapped the obsolete bq34z100 IC to the newer bq34z100-g1.

My goal is to get the gauge working with 24V lead acid battery. I started simple using 1 single Liion cell, this works fine.

(For the 24V battery I did changed the jumpers to >5V on the EVM)

Thanks!

Leon


Viewing all articles
Browse latest Browse all 35901

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>