Hi
I am currently having an issue with the BQ27411 device internal to a pack - roughly speaking I have a battery pack that contains a charger and coulomb counter. The cell is 2600mAh single cell, however I am unable to get a true representation of the SOC or the available capacity. If the cell has been charged until the charger IC (BQ24257) indicates the cell is full the SOC states 100% but only 400mA capacity. I am wondering if the issue is that it is always connected to this charger, and would the BQ27531-G1 be a better alternative?
Thanks
Allen