Hi!
BQ40Z50 (refman) 12.4 0x03 BatteryMode() have
CF (Bit 7): Condition Flag (R)
0 = Battery OK
1 = Conditioning cycle requested
after success learn cycle CF 1->0 - this is forever?
if I send "Reset command" from bqStuduo to bq40z50, chip make reset but CF=0
what conditions set Flag CF0->1 ?
for example bq2060 (refman):
"RELEARN_FLAG bit set indicates that the bq2060A is requesting a capacity relearn cycle for the battery. The bq2060A sets the RELEARN_FLAG under any of three conditions: full reset, detection of 20 cycle counts without an FCC update, or a midrange voltage correction. The bq2060A clears this flag after a learning cycle has been completed."