Bq34z100-g1 question regarding scaling factor and design energy field

$
0
0

Greetings,

16s2p lithium.  57.6V 5.6Ah

I am setting up a BQ34Z100-G1 with a battery pack.  I have determined that I need a scale factor of 2 for the battery voltage parameter, and set the scaled bit and volsel bit, and understand calibrating voltage at divide by two and setting number of cells parameter at divide by two as well.

My pack capacity 5660 mAh and max current 26A is less than max gauge parameters, so I don't need to scale them necessarily.

My question is that since I am scaling volage, do I have to scale current/capacity?

And there is a parameter in the gauge setup "Design Energy" in mWh.  57.6V nominal x 5660 mAh = 326016 mAh.  I would have to scale this by 10 to fit?