BQ40Z60 – Need help setting up Voltage Based Shutdown parameters

$
0
0

I setup Voltage Based Shutdown and get the following behavior:

With no charger plugged in, when Min Cell Voltage goes below Shutdown Voltage, DSG FET turns off for less than a second then turns on again. After a few more seconds this cycle repeats until Min Cell Voltage remains below Shutdown Voltage while DSG FET is off. We are drawing about 500mA when DSG FET on. 

 

The behavior I would like is once in Shutdown, the DSG FET remains off until ACP > V startup as opposed to cycling on and off until battery is drained further.  Below are the settings I am using:

  • Shutdown Voltage 3000mV
  • Shutdown Time 5 S
  • Charger Present Threshold 10000mV
  • Power Off Debounce 8x250ms

Questions:

  1. Is V startup the same as Charger Present Threshold? I didn’t see where V startup can be set.
  2. According to SLUUA04-December 2014, 5.4.1, once in SHUTDOWN mode, it should require Voltage at ACP pin > V startup to EXIT. Any ideas what could cause the cycling on and off that I am getting?

Warmest Regards,

David