Gauging Parameter Calculator / NumCellSeries setting

$
0
0

Hi,

Please let me ask about NumCellSeries setting at GPC. I know that you have following three tool.

  1. Chemical ID Selection Tool
  2. GPC Golden GG Maker Tool
  3. Golden GG Maker and Resistance Temperature Compensation Optimizer

I read each app note and check NumCellSeries setting, then I found following comment in only 2 and 3.

"Note that if your battery pack has 3 series cells, but your log file is for a single-cell voltage as is recommended, this value should be 1"

In the case of 2s application, should NumCellSeries setting be 2 at "Chemical ID Selection Tool", and should be 1 at "GPC Golden GG Maker Tool" and "Golden GG Maker and Resistance Temperature Compensation Optimizer" ?

Best Regards,

Sonoki / Japan Disty