BQ40Z50-R1: Cell 1, Cell 2 low voltage on 3 cells in series battery pack

$
0
0

Part Number: BQ40Z50-R1

We have 2 battery pack models that are using BQ40z50-r1 (Model A:3S2P and Model B:3S1P).
 
Regarding the failure we found, during inspection we saw that 3 batteries have almost 0V voltage on Cell 1 and Cell 2, but Cell 3 (B+) is still around 3.4V .  These battery packs have were never been used and have about 300hours of FW runtime in the extracted GG files while the rest of the good batteries have about 8months of FW runtime.
 
The 3 batteries were already in shutdown mode.
After waking up the gas gauge IC, we saw CUV and SUV after checking SBS.
 
 
After inspecting the PCB, we didn’t see any physical shorts in the circuitry or burn marks on the PCB that may
show any short and drain the cells.  The impedances of the capacitors across and resistors connected to VC1,
VC2 and VC3 seen in the table below.
We are also using BQ294700 in the PCB for secondary protection IC and impedances of capacitor and resistors
below:
 
Model A (1)
Model A (2)
Model B
C6
2.85MΩ
2.78MΩ
2.79MΩ
C7
2.2MΩ
2.34MΩ
2.23MΩ
R6 (100Ω)
104.48Ω
104.82Ω
103.92Ω
R7 (100Ω)
103.96Ω
104.72Ω
104.83kΩ
C3
2.85MΩ
2.78MΩ
2.79MΩ
C4
2.2MΩ
2.34MΩ
2.23MΩ
R3 (1kΩ)
0.994kΩ
0.9957kΩ
1.005kΩ
R4 (1kΩ)
0.992kΩ
0.9978kΩ
1.006kΩ
 
After inspecting the parts, we also retested the PCB and found that the consumption current and function of the ICs are found
within acceptable values.
 
Normal
Sleep
Shutdown
Model A (1)
291.0uA
82.9uA
2.3uA
Model A (2)
290.4uA
73.2uA
2.3uA
Model B
282.4uA
83.9uA
2.3uA
 
 
We came across this in the forums.  Although the issue looks different because we didn’t have COV,
 
Have you seen cases from other customers seeing the same issue where the cell voltages became imbalanced and eventually
become low voltage when the batteries are stored and at sleep mode?
We find that it is curious to find both cell 1 and cell 2 are drained on 3 batteries and was seen on two different models and if it
was a cell issue, we should be randomly seeing low voltages at cell1, cell2 and cell3
Thanks in advance!
Kenny