BQ76200: DSG and CHG don't remain ON and VDDCP maybe is too low!

$
0
0

Part Number: BQ76200

Hello,

I' m usind following schematics for my circuit: 

For Charging part:

with RCHG = 470ohm, Rb=100ohm, Cb=10nF, Rgs_chg2=4.7Mohm, Rgs_chg1=10Mohm

For discharging part:

with: Rdsg=470ohm, Rgs=10Mohm, Rp=56ohm and capacitor beetwen VPack and rp=10nF.

The capacitor beetwen VDCCP and Vbat is 1uF.

The VBat is 12.4V.

 CP_EN is alway ON,

PMON_EN and PCHG_EN are Always OFF.

The mosfet Q1, and Q2 are STL120N8F7  (but I tried also BSC010N04LSI).  I don' t have PCHG mosfet.

Whit CHG_EN and DSH_EN i have this:

Yellow=VDDCP

heavenly=VBAT

but when I switch ON CHG_EN and DSG_EN I get these on DSG:

Yellow=VDDCP

heavenly=PACK pin 

pink=DSG pin

and this on CHG:

Yellow=VDDCP

heavenly=BAT pin 

pink=CHG pin

I tried to change the Vddcp capactor from 10nF to 22uF, but never changed except the start time.

I tried to change the Rchg and Rdsg from 0ohm to 33kohm but never changed. 

I don' t understand why it doesn't work!!!