Hi All
I'v been hammering at the bq34z100q1 for a week or so.
My setup.
I2C comms with 5 LEDs.
3 cell series ( Li-Ion pack 5200mAh at 11.1Volt)
I can communicate with the bq34z100g1 via EV2300 on my custom board and it seems that it states the battery is charged at 100%.
Few questions
1) Does the fuel gauge now adjust the led's on as per the % of charge and will it again switch more LED's on when I'm charging the battery
2) What is the correct way to calibrate my setup?
3) what happens to the calculation when the battery is disconnected and the connected again?
4) Why is the documentation so poorly documented? One needs to search high and low for the meaning of the abbreviations in the Data Flash summary table.
Please find attached my "golden file" and exported settings.
Thank you for your time
BDD(Please visit the site to view this file)