BQStudio and Learning phase

My goal is to use the BQ27421 and BQStudio to characterize several batteries and create a "golden image" to eventually program the chip in our design.

BQStudio has a lot of capability but apparently no central document to describe its use.  

I completed the Parameter Q&A and intended to start the learning function manually.  Following are questions I have regarding this process and BQStudio use:

1) A support member sent me a powerpoint presentation on a "deepdive" on BQStudio.  It showed a window in Windows/Settings/Registers that allowed you to set Conditions to Start Charge (or Discharge).  I don't see these options in my setup.

2) This window would activate the "EV2300 I2CSDA/HDQ line HIGH (and I2C Vout = LOW)" upon set check conditions.  But what is I2CSDA/HDQ?  The HDQ port only has VCC/HDQ/VOUT/GND pins.  

3) After completion of a manual discharge, the software goes into Relax state.  The only way I found to get out of it was to pull the USB cable to the pc. Then it says I can go into Charge phase.  Is there a better way?

4) Upon then starting charge phase, the Data Graph shows the battery voltage rising but the I had selected Average Current and State of Charge and they are bogus (-11666 and 0%). Why?