Hi All gas guys
I'm busy with the bq34z100g1 now for about 2 weeks and every day I learn something new.
What are the correct way to
1) Reset a bq34z100g1 to factory default?
2) Step for step instructions to create a golden file for my battery pack
Here is what I have done
1.1 Unsealed the bq343z100g1 using the command button on the right
1.2 hit unseal_full_access button on the right
1.3 hit the RESET button on the right
For 2
2.1 Full charge a battery in a different charger ( out of circuit of my bq34z100g1)
2.2 upload my chemical file for SAMSUNG 18650-26H
2.3 update my data memory of the design capacity to 5200mAh
2.4 update cell in serie to 3
2.5 make sure Design energy scale is at 1
2.6 changed my LED_Config to 5 LEDS with I2C
2.7 calibrate my cc offset and board offset and applied voltage
2.8 discharge the battery with my load(not switching off the system)
2.9 wait 2 hours (never switching off)
2.10 charge battery via the bq34z100g1
2.11 wait 5 hours
2.12 repeat step 2.8 to 2.10
2.13 create golden file
This correct?
Kind regards
Ben