Correct way to create goldenFile for BQ34z100g1 with bqStudio

Hi All gas guys


I'm busy with the bq34z100g1 now for about 2 weeks and every day I learn something new.

What are the correct way to

1) Reset a bq34z100g1 to factory default?

2) Step for step instructions to create a golden file for my battery pack

Here is what I have done

1.1 Unsealed the bq343z100g1 using the command button on the right

1.2 hit unseal_full_access button on the right

1.3 hit the RESET button on the right

For 2

2.1 Full charge a battery in a different charger ( out of circuit of my bq34z100g1)

2.2 upload my chemical file for SAMSUNG 18650-26H

2.3 update my data memory of the design capacity to 5200mAh

2.4 update cell in serie to 3

2.5 make sure Design energy scale is at 1

2.6 changed my LED_Config to 5 LEDS with I2C

2.7 calibrate my cc offset and board offset and applied voltage

2.8 discharge the battery with my load(not switching off the system)

2.9 wait 2 hours (never switching off)

2.10 charge battery via the bq34z100g1

2.11 wait 5 hours

2.12 repeat step 2.8 to 2.10

2.13 create golden file

This correct?