Dear Sir,
I am using bq40z60 based circuit where I tested with applying voltage. The Software is detecting starting from 3V AC power to 13V as our power supply. I am getting the voltages of pins REGN,ACFET,VCC pin perfectly. But I am not able to get HIDRV voltage more than 4.2V because of that Battery is not charging. Iseen that my problem on HIDRV only so that the FET is not enabled and not going to Inductor, Battery and also to System Load out. Also the Charge CHG and Discharge DSG FET showing 20.6V means that FETs too are enabled. Kindly give some suggestion on this problem with HIDRV (PWM High Side Driver).
Thank You.
Regards,
S.Rameshkumar