BQ79606A-Q1: Problem waking it up for the first time

$
0
0

Part Number: BQ79606A-Q1

Dear TI experts,

We are working on building our own BMS and we have opted to use your BQ79606A-Q1 but we have some issues.

We have a BQ79606A-Q1 with the needed electronic components and connections made, and we am trying to make it balance 6 Li-ion cells also connected, but the problem appears when trying to wake it up in order to start balancing them. For the wake up we are sending from an arduino a low bit for 250 us (microseconds) and then a high bit for more than 30 us to the wake up pin (the 16th) as said in the datasheet.

Then, even we don't send anything else, the BQ should start running and doing his job, shouldn't it?

Are we doing something wrong at the process of waking it up? 

Best regards,

Alex


Viewing all articles