HI,
I am trying to write to the data flash on a new battery design using the BQ20z65-R1 v1.05, but the aval software does not seem to be able to update the data flash. When I write to any of the registers they just turn red and revert to their original value. The SMBus communication works with all the SBS registers being read correctly.
I tried using bqChem and when that tries to write to the BQ20z65-R1 in order to update the chemistry, I get the following error: Writing Chemical Data, bqChemOCX - Fail read Verify, Abourt SubClass83 programming.
I can write to ManufacturerAccess, e.g. turn on the LEDs.
Flags/Status register summary:
BatteryStatus = TCA, TDA, INIT, DSG
OperationStatus = PRES, DSG, R_DIS
Do you know why I cannot write to the data flash?
Many thanks