I am using bq Gas Gauge Eval s/w bq34z110 v0.04
Is it normal that, during a "Step 8 Optimization Cycle" on a 12V 7Ah Yuasa PbA battery, a few minutes after the Flags.DSG bit is set, the Flags.CHG bit is also set.
Charging was done using bench psu set to 13.8V. Discharge using resistor.
Relevant settings FYI:
Dsg Current Threshold = 10mA
Chg Current Threshold = 75mA
Quit Current = 40mA
Dsg Relax Time = 60s
Chg Relax Time = 10s
Quit Relax Time = 1s
I am also having considerable difficulty changing any of the Data Flash settings. Are changes to Data Flash settings prohibited when IT is enabled?
Thanks