Quantcast
Viewing all articles
Browse latest Browse all 35901

bq40z60 not charging, DSG = 1

Hello,

I've made my own BQ40Z60 board, which is the same as BQ40Z60-EVM excepted the following change :

- traditional fuse (no external burning)

- no 2nd degree protection (BQ294700)

- I want to charge at 1A and I want to improve resolution, so Rchg=30mOhms and Rsns=20mOhms

- fixed in 3S configuration

I’ve made 3 boards and checked, checked and rechecked hardware : so the 3 boards seems really OK.

One is charging, the 2 other work well (measuring current, voltage, adapter voltage,…) but no charge.

The only differences I’ve notice in registers are :

- Battery status and gauging status : DSG = 1 on non-charging boards instead of 0 on charging board.

- Charger status : CHGSTAT = 0 on non-charging boards instead of 1 on charging board.

- operation status A : BTP_INT = 0 on non-charging boards instead of 1 on charging board.

Do you have an explanation or other test to help me resolve this problem?

Regards,