Quantcast
Channel: Power management forum - Recent Threads
Viewing all articles
Browse latest Browse all 35901

BQ27426 configuration

$
0
0

Hi All,

I'm using the BQ27426 in my new design. To understand what parameters i need to change i connected my BQ27426 to TI battery management studio.

Im using a li-po 110mAh 3.7V  battery.  i have a few questions:

1. As i understand from the data sheets ( and maybe im wrong) the critical parameter are:

1.chemistry -( i set it to 1202)

2. design capacity - i set it to 110mAh

3. termination voltage - 3400mV

Do i need to change more parameters to get a SOC ?

2. Does the BQ27426 preform a learning cycle automatically or i need to sand a command?

3. i have a strange problem after one cycle (charge-discharge) my SOC dosent updated. any one know what can cuse this problem?

4. im working with a micro controller a a master in my system, each time i turn off my system and on again i need to write the parameters(chemistry , design capacity etc.)   to the BQ27426 ? does the BQ27426  save his learning data or i need to save something in the micro controller  memory before turning off my system?

thanks for the help