BQ27411-G1: BQ27411-G1 read data problem

$
0
0

Part Number:BQ27411-G1

Hi all,

We have a custom board with BQ27411-G1.

We are trying to read the device ID from  BQ27411-G1.

Most of the time master fails to read the device ID.

Our procedure are as follows

Start , device address=0xAA,  control reg1=0x00, subcommand 0x01 ,0x00, stop

delay 1S

Start, 0xAA ,0x00, repeat start, 0xAB, 1 byte read, stop

We captured the write and read data using logical analyzer. In firmware, We are giving 0xAB after repeat start But, read address is incorrect in captured data.

I have attached screenshot for reference.

 write command

Correct Read 

Incorrect read

We have tried FW_VERSION and CHEM_ID but  problem remains same.

Am I missing anything on read command?

Regards,

Kayathri