Hai,
I did the learning cycles and I got the golden .DFI through the evaluation software. I needed to clarify one thing , I gave the Design Capacity to be 5800 mAH (by two 2900mAH NCR18650A cells in parallel),now during the learning cycle I could see the update status going 1 and 2 and the Qmax values came to be somewhat above 6000 mAH and in dataRAM too I could see the full charge capacity as above 6000mAH but after going through updating golden pack process the Qmax values came back to 5800 and the capacity indications in dataRAM also came out to around 5800 like 5732 mAH.
So I wanted to confirm whether there is any sort of error in my learning Cycle….