OCV value read

$
0
0

Hi,

I'm testing bq27520G3EVM learning cycle with bqEASY. At the end of charge, FC bit is set. During relax, VOK is cleared but App Status never change to 01. Slua544 "Generate Golden Image" shows that the gauge take an OCV1 measure before Enable IT.

1) When OCV1 measure is taken ? In bqEASY step 5.1 by clicking Dsg/Wait Done or 5.2 Initialize IT ?

2) Where can I check if OCV1 measure happens ? (RAM, Flash ?)

3) After automated discharge to 3V at C/5 and relax 5h, battery voltage reach 3,43V. Is it too high to enable IT ? (Chem ID = 0162)

4) After charging, VOK is cleared during relax (30 min). Does App Status should update to 01 at this changing state or it will be updated after 2h relax ?

Thanks for help.

Pierre