Hi
I am having a problem getting the OCA to set on a BQ20z45-R1 based battery when RSOCL = 1. It seems that because the RM and RSOC are limited to 99% until a valid charge termination occurs that the over charged condition is not being detected.
I have attached two log files, one with RSOCL set and one with it cleared.
Over Charge Capacity is set to 50mAh.
I can send the dataflash settings separately if required (they are confidential).
Is it possible to get an OCA when RSOCL is set?
Many thanks
Steve