bq77908A: OCD/SCD fault recovery possible with partial load?

Can the bq77908A recover from a OCD/SCD fault if the load has not been disconnected entirely but just dropped significantly in value?

We have an application where we'd like to shut off the discharge FETs at 100A-200A (depending on pack configuration) but have the FETs turned back on as soon as the load drops back down to its regular operating level, anywhere from 5A-30A. The load would not be disconnected, only reduced, after a short circuit or overcurrent event. SOR would be set to zero.

After reading the datasheet it seemed that the load needed to be completely disconnected for recovery to occur but I was hoping, if that's true, that a workaround existed.