BQ34Z100 IT Cfg configuration

$
0
0

Hi Tom,

After trying with the setting as suggested, we do not see SOC jumping but there is another problem occurs where both full charge capacity and remaining capacity will drop from 39600mAh to 7000mAh while discharging and SOC stays at 100%. I tried to set max sim rate to 2 by taking the default value suggested in 'Configuring the bq34100 Data Flash' and it solves the capacity problem. Do you know whats the causes of this problem?

Actually have some doubts regarding the configuration for Impedance Tracking. According to the datasheet if we are selecting Load Mode as constant current, there are a few options available for load select. Do you mind to explain in more detail on how do we judge which option shall we select and also how does max sim rate and min sim rate work? If we are using  User Rate-mA,  for example ,User Rate-mA has been set to -1A, we should discharge the battery at 1A in order for FCC simulation to run properly? 

Thanks.

Best regards,

Shirley