compatibility bq27541 to bq27500

Can I put a DFI file in a bq27500 v113 to create by using a bq27541 v200?

View Article


use of BQ27510 for primary batteries

Hello-We have integrated the BQ27510 into our system that uses 3 series L91 Lithium cells. These cells are primary cells and are not rechargeable. Our issue is that everything we read about the...

View Article


Image may be NSFW.
Clik here to view.

BQ34Z100 GG Mode Error

I have a bq34z100 chip in an original board design and am experiencing issues with the gas gauge mode. The chip calibrates correctly for voltage and temperature, but gives me an error when I try to...

View Article

BQ28550-R1 no I2C communication

Hi,We have a design with a BQ28550-R1 gas gauge coupled with a BQ24072 charger.The gas gauge gets correctly woken up (turning FETs on) when the charger is connected and it also turns OFF the FETs when...

View Article

BQ27510-G2 lost yIFRowData

I lost yIFRowData to due my program error.I can send the DFI file to device but the process stop at Figure 10 of sluas449e.pdf. Can I resolve this or must replace device with new one?Thanks

View Article


BQ27510 - After connecting battery, device comes up in ROM mode

Hello,My system has a battery that can be disconnected and reconnected.  Currently I am doing firmware development using Code Composer Studio.  Therefore when I reset the system, I disconnect the...

View Article

bq27421-G1 / Benefit of high-side sending

Hi Team,I would like to promote TI's new fuel gauge device of bq27421-G1 to our customer, then I would like to know the benefit of high-side sensing. I believe that bq27421-G1 is similar to bq27425 but...

View Article

Image may be NSFW.
Clik here to view.

bq34z100 - flag "FC" is not set if "FC set% =-1"

Good day!If you set the FC Set% =-1, the flag FC is not set at all.  Though- Average Current is < Taper Current- Voltage > Charging Voltage – Taper Voltage- capacity > 0.25 mAh perCurrent...

View Article


Bq26200

Dear sir,I am working on smart battery using your Circuit BQ26200. I have some Doubts with it 1) Is it is possible to do calibration using power supply or we have to use cell pack . 2) and what  are...

View Article


BQ3060 Current and Temperature Calibration

Hi,I'm working on an automated BQ3060 data flash programmer and calibrator for use in manufacturing.  The only documentation I have found on calibration is SLUA502.  In this document, the example...

View Article

bq78pl114 Сonfiguration

Hi,I have a problem.USB-TO-GPIO adapter is Damaged.How can Iconfigure and use the bq78pl114 without an adapter?Whenreadingany of the settings, I get a 0xffff, but ACK going to low.  Why?When I Read...

View Article

Problems writing Data Flash BQ3060

Hi Community,I am trying to write via the SMBus the Data Flash of the BQ3060 Gas Gauge because I have to set a few parameters different as default settings. For example I would like to change the high...

View Article

BQ20Z75DBTR-V160 I2C latch-up

We are working on a Battery Management system which its battery pack is installed with BQ20Z75BTR-V160 gas gauge. The communication lines (i.e. SMBD and SMBC bus) circuitry is as per page 15...

View Article


incorrect definition of capacity

Good day!I can not understand why the battery 13,4Ah  shows when charging 32Ah (Passed Charge). Current and voltage correct. As calculated  a parameter Passed Charge?Thank you

View Article

Image may be NSFW.
Clik here to view.

How can I read data from bq34z100

Hi,I have same problem with block memory reading. I want read the Manufacturer Name in Data Subclass. Manufactured Name have offset 55. I try as below:WriteByte(0x61, 0x00) //enable flash...

View Article


Problem obtaining a good learning cycle with bq27510

Hi,I am trying to do a successful learning cycle but I always get the error UpdateStatus does NOT=2 at the end. I checked the problems that are explained in slua597 but still can't understand mine....

View Article

Chemistry Selection: Sony US18650VTC3

Hello,I'm looking for the best chemical ID file for Sony US18650VTC3. I have downloaded the latest Chemistry Updater, but I can't find this model.I don't have Mathcad, here is the datalog :(Please...

View Article


bq20z45-R1 reading parameter Min and Max value

Please tell me the Min and Max value of the following reading parameters.-Temperature-Voltage-Current-Cell Voltage[1:4]In the datasheet, each parameter register has Min and Max value.ex) Voltage: Min...

View Article

How to read out the Data Flash of BQ3060

Hello everybody,Can anyone explain the procedure how to read out the data flash?I am not sure how the Slave send the Data. Is it always 32 bytes? Or is it send at first the number of following bytes in...

View Article

bq20z95 temperature calibration error code

Hello,When I try to calibrate the temperature on a pack using the bq20z95 and using the bqEval software, I get the message "Calibration Failed! Error Code = Error Code (decimal) 5027"Any idea as to why...

View Article