Quantcast
Channel: Power management forum - Recent Threads
Viewing all 35901 articles
Browse latest View live

BQ20Z655-R1: Not going to sleep.

$
0
0

Part Number:BQ20Z655-R1

I cannot get my unit to sleep. I'm not seeing either the CHG or DSG FETs turn off.

I have a non-removable battery so [NR] = 1 in CfgB. I have set my sleep current higher than I need (50mA) for testing purposes. When "idle" I'm seeing about ~3mA of absolute current. I don't understand why it won't sleep. 

The 'PRES' pin on my design is grounded. But  I have read that "If the [NR] bit is set, the PRES input can be left floating, as it is not monitored." So I'm am interpreting that this is not the issue, correct?

Also, sending an 0x11 in the manufacturer access line does not send it it sleep either.

I have attached my .GG file.(Please visit the site to view this file)


BQ40Z50-R1: bq40z50-R1 / Coulomb counting during cell balancing

$
0
0

Part Number:BQ40Z50-R1

Hi,

Please let me ask about coulomb counting during cell balancing. I understand that the charge current is bypassed during charging or at reset. Then the bypassed current during charging is not flowed to cell so this can't count as charge current. And also the  bypassed current at rest is not flowed through sense resistor so this can't count discharge current. In fact I think that the bypassed current will produce the error of calculated capacity. I'd like to understand about it so please share any app note or presentation material if you have.

Best Regards,

Satoshi / Japan Disty

BQ40Z60: To know whether bq40z60 can be used for a Li ion polymer battery pack system with 2 serial cells

$
0
0

Part Number:BQ40Z60

I am using a Li ion polymer battery pack system with 2 serial cells. The pack has three terminals - pack+ pin, pack- pin and NTC pin. Individual cell terminals are not accessible.

My question: whether can I use bq40z60 for this configuration? If yes, what limitations I will have in the design.

BQ27421EVM-G1A: Ra value setting method of BQ27421-G1A

$
0
0

Part Number:BQ27421EVM-G1A

Dear, All

"3. GPC - Optimize room and low temperature performance. Includes (2)."
Log data was uploaded to the above system.
As a result, due to problems, I have two questions about the bq 27421-G1 Technical Reference.
The first question is about Qmax Cell 0 formula.
"6.4.2.3.1 Qmax Cell 0"
The following equation is described.
Qmax (mAh) = Qmax Cell 0 × Design Capacity / 2^14
If Qmax Cell 0 is Default value, does this mean the same value as Design Capacity?
In this case, in GPC_report
Qmax, mAh: 233195
And it was output.
This value does not match.
What should I consider?

The second is the setting value of Ra.
The following values ​​were specified as NewRa.

DOD Ra, mOhm
0 2
0.111 2
0.222 2
0.333 5
0.444 3
0.556 3
0.667 4
0.778 5
0.81 6
0.841 5
0.873 5
0.905 6
0.937 10
0.968 26
1 32

An expression to convert it to a value for setting R_a RAM from this value was not found.
Please tell me this equation.

Thanks, Masami M.

BQ27542-G1: Can't start learning cycle

$
0
0

Part Number:BQ27542-G1

I tried to return default configuration using .srec from this thread - e2e.ti.com/.../552849

But after programming, I cant start learning cycle, after sending IT_ENABLE nothing happens. QEN = 0, VOK = 0, RUP_DIS = 0.

How can I start the learning cycle again?

BQ27220: GPC packager in Bq studio

$
0
0

Part Number:BQ27220

Hi ,

I  am planning to  take log  for GPC tool  with  Bqstudio for Bq 27220 but i could n't bale to find GPC packager. IC is automatically detected by software. Please let me know if I am doing anything wrong. 

BQ27520-G4: WDT set or reset

BQ78350-R1: Reading information form the Manufacturer Data register (command 0x23)

$
0
0

Part Number:BQ78350-R1

Hello,

We are working on a 5s Li-Ion battery pack that uses the bq78350-R1 fuel gauge in conjunction with the bq76920 AFE. Our customer requires that we program a certain string of information into the Manufacturer Info register, which is read  by their device using the read Manufacturer Data command 0x23. However this command does not always return the correct data. It doesn't seem quite clear in the bq78350 Technical Reference Manual, but it looks like the Manufacturer Data command is also used to read calibration data as well as some lifetime data.

What is the protocol to read each of the different sets of data? We need to be able to read the Manufacturer Info string every time the read command is issued.

It also looks like every time we use bqStudio to read battery  information, the read manufacturer data command changes 'modes' and reads the different sets of data.

Any help is greatly appreciated. Thank you,

Maciek


BQ27742-G1: Checksum for Authentication query

$
0
0

Part Number:BQ27742-G1

Hi ,

I am using battery gauge BQ 27742-G1. How do I calculate the checksum for key programming and executing an authentication query? Is there any difference between these two checksums?

Regards,

Riya

BQ27220: Regarding link provided in the datasheet

$
0
0

Part Number:BQ27220

Hi,

In  the  datasheet Bq27220 there is  a link  provided  for quick start guide 

Quickstart Guide for bq27220 (SLUUAP7) which is basically quick start guide for impedance track gauge. Please let  me know can I follow this quick start guide for my part which is basically CEDV based gauge. Please provide me similar quick start guide for CEDV based part.

 

BQ28Z610EVM-532: how to discharge BQ28Z610

$
0
0

Part Number:BQ28Z610EVM-532

hi,

I have follow the

How to use the bq28z610 EVM available at https://e2e.ti.com/support/power_management/battery_management/f/180/t/551498 with EV2300 and the kit manage to charge up the battery.

However, when I remove the power supply and I expect the fully charge battery to kick in and continue to supply to the evaluation board so that I can continue to use the BQstudio to monitor the discharge. What I saw is the I2C connection is disconnected and Bqstudio is not able to detect the eval board? My question is why the fully charge battery cannot use to supply the power to use the eval board? Can I do this?

If cannot, how do I monitor the discharge?

On my own PCB board, I received the error 1470 when I try to program the chemistry. how do I get rid of this message?

Best regards,
Kpk

BQ27220: Regarding Quick start guidelines

$
0
0

Part Number:BQ27220

Hi  Team,

We are  using Bq27220 in one of our application,  I am  getting confused from the links provided in the datasheet, all these  links  refer to Impedance track part, but Bq27220 is CEDV based  gauge

 As per my  understanding, i have to do at least following steps in order to get gauge working

 A) update parameters in RAM as per my battery and upload the various log file in GPC calculator for getting Compensated End of Discharge Voltage (CEDV) coefficients.

B) Then I will  get the nearest profile parameters which have to be programmed  in OTP  memory

Now  I have  following questions 

1) Does my understanding is correct?

2)  What are  the minimum parameters which have to be updated before  taking logs.

3)What are the data I will get after uploading log files?

 

BQ28Z610: Charging cannot be activated

$
0
0

Part Number:BQ28Z610

I would like to ask the BQ28Z610 disconnect the battery can not charge activation, what is the reason

BQ34Z100EVM: NIMH battery pack

$
0
0

Part Number:BQ34Z100EVM

Can the EVM be used with NIMH battery pack (nickel metal hydride)?

EV2300: Firmware update, anyone in Brisbane or Australia with a EV2300 or EV2400 to do a FW update?

$
0
0

Part Number:EV2300

Hi battery peoples,

I have a EV2300 which needs the latest firmware applied to be used against a BQ40Z60 which I intend to use in a new battery pack. Any one in Australia, or even Brisbane who I can ship my device to to perform a firmware update on?

Will provide return express post bags etc :)


BQ40Z50-R1: External Balancing Reference Design/Application Note

$
0
0

Part Number:BQ40Z50-R1

Hi Sir/Madam,

Is there any external balancing reference design or application note for BQ40Z50-R1 available?

Thanks. Hope to hear from you soon.

BQ27220: Using Bq27220 without GPC calculator

$
0
0

Part Number:BQ27220

Hi we are using  Bq27220, as per my understanding  we need  to update CEDV coefficients, for that, we need to submit 6  log files at a different temperature which is time to consume for us as our battery capacity is too much. Please let me know if we can use  gauge by just updating required parameters. Also,  please  how it will impact performance  of gauge if we are not doing process for  updating CEDV  coefficients

BQ27411-G1: Bq27411 Calibration problem.

$
0
0

Part Number:BQ27411-G1

Hi, TI,

If the current accuracy is -600mA, it will be 11mA. (± 3mA for IC SPEC)
Current CAL ... bqstudio does not have a window to do cc offset cal.
In bqstudio, we calibrate manually using 'board offset' & 'pack calibration'
It is possible to do
DATASHEET also has no CMD for CAL ...
If you have CC calibration method, please reply.

Thank you.

BQ78350: bq76pl455

Please help me when j find evolution software for BQ30Z55

$
0
0

Hi Please help me when j can download a evolution software for bq30z55 in software number is 550_0_36_3_0034

Viewing all 35901 articles
Browse latest View live


Latest Images