I am trying to create a golden image for the BQ27510-G3 gas gauge. I have determined the correct chemistry type for my battery and use this (1116) when running bqeasy in the bqEVSW application.
I have tried the learning cycle 3 times already, but what I see is that the RA tables are not (never) updated during the discharge cycle. In other words, the update status is never set to 0x02.
The first cycle, charging until full, is executed without errors. I see that the update status is eventually changing to 0x01 , and I see that Qmax for cell 0 is set at 506 mAh.
My battery has a capacity of +/- 550 mAh. The discharge current starts at -100[mA] and eventually ends with a value of +/- -70 [mA]
Could you please advise me?