Over temperature detection during charge using BQ78350 and AFE BQ76930 - OTC flag not being set. OTD is Ok.

$
0
0

Using BQ78350 and BQ76930 combination for BMS.  Temperature reading ok and Discharge FET turns off (during OT in discharge).

The OTC flag does not come on during charge and verified the following :

1. FET options  OTFET is enabled

2. Enabled Protection A - 0xFF

3. Enabled protection B - 0x0F

4. Enabled Protection C - 0x15

5. Permanent Fail A - 0x10

6. Permanent Fail B - 0x30

The Charge FET does not  Turn OFF during Over temperature. Also verified charge current is present.

Any other settings i am missing?