bq78z100: Gauge does not track after programming unless Reset is applied after batteries are discharged

Part Number:bq78z100

Hi,

I'm employing a battery programming procedure where new batteries are programmed (using firmware update with a golden srec file) then discharged to empty, then shipped to customers.  Often times the batteries are assembled with cells at 30-50% capacaity in them. We're seeing that the State of charge does not track unless a reset is applied when the batteries are discharged.  We do not want to over-discharge the cells so we stop discharging at approximately 6.9V.  Fullycharged, the battery sits at 8.2 to 8.4V.  Here is data on one of these batteries:

VoltageState of Charge
After programming7.45957%
After discharge7.0557%
After Reset7.0519%

Is there something wrong with my golden image or my programming procedure?  Does a reset have to be applied after cells are discharged or is it the programming that needs to be performed after cells are discharged?

I have attached files for my golden image. 

-Yan