Current sense Resistor.

Hello.I can´t calibrate a BQ27510 V1.2 with a 20mOhm current sense resisto, when I read Data Flash, a 10mOhms resistor is configurated. In other one device I calibrate it at 20mOhms without...

View Article


Calibrate battery with BQ34Z100PW

Hi,I've a problem with the calibration of my battery with the BQ34Z100PW.My battery specs:26.4V12 Ah 316.8WhThe problem is my capacity in the data ram isn't the same as the design capacity I programmed...

View Article


Cannot complete Impedance learning cycle of BQEasy

Every time I go through the 2 day battery learn process, at the very end it errors out saying the CB bit is not set. I have the calibration window closed.  SBS is not set to repeat.  I have not changed...

View Article

Values of CC Gain and CC Delta

I am not using the evaluation software, but i am using a microcontroler with i2c to communicate with bq and I did already some writes and reads from flash I am using the bq34z100 and a I have a doubt...

View Article

BQ27421-G1 Sample Codes

Hello,Are there any sample codes for the BQ27421-G1 fuel gauge?I have a customer looking for code examples to be incorportated into his embedded code.  I've provided the EVM User guide, quickstart...

View Article


Mathcad ChemID help

I'm using a Vision CP12170X (12V 17Ahr) sealed lead acid battery and I want to know the ChemID. I've performed the steps explained on "Chemistry ID Selection":Charge the pack to full and allow it to...

View Article

BQ34Z100 battery capacity

Hi,I have some questions regarding battery capacity reading of BQ34Z100.Is it normal that the full charge capacity jumping up and down while charging or discharging if the battery hasn't gone through...

View Article

Where exactly does the BQ27741-G1 'CVM' status bit come from?

In the bq27741-G1 user guide ( http://www.ti.com/lit/pdf/sluuaa3 ) on page 36 it mentions this status bit: CVM = Cell voltage monitor threshold 1 = Cell voltage monitor threshold detected 0 = Cell...

View Article


Design Capacity is also used by the gauge in RemainingCapacity( ),...

In the document "SLUA656–December 2012", Configuring the bq2754x-G1 Data Flashpage 7Design Capacity stores the typical capacity, in mAh, of the cell being used in the system. DesignCapacity calculates...

View Article


Measuring Current between two 12V 250Ah batteries with bq34z110

Hi,I need to measure currents between two 12V lead-acid batteries (250Ah each) and need to monitor SOC and SOH of both batteries.Is this possible with two bq34z110's?|GND|---------|(-) BATTERY1...

View Article

BQ34Z110 REGIN

Hi,could  the voltage at the REGIN pin of bq34z110 when connected to 24V lead acid battery (2 batteries in series) be closer to 7.48 V? In this case I've also  found the internal temperature (by using...

View Article

Unseal BQ20z45

Hello,I need the unseal key for the BQ20z45.please send it to boris.mayorov@mail.ruThanks

View Article

flashstream and dfi

Hello,Like others in this forum, i need help with programming our gas gauge (BQ27500-v130) for production.  Could someone send me the latest version of flashstream and anycode (preferrably in C) and...

View Article


battery does not charge to full

hie there againwhen i reset  bq2084 and 20z70 based batteries whose FCC have droped bellow or risen above the manufacturer FCC value,when i then try to charge using an external non  udjustable power...

View Article

TI USB-GPIO adapter not communicating with bq77910A

The message I get is:Incompatible Firmware VersionAttention: The USB-GPIO interface adapter version is not compatibleDetected version: 1.0.10Required Version: 2.0.19It is recommended that you update...

View Article


Samsung EB-L1G6LLU Chemistry ID

I am using bq27500 gas gauge with an EB-L1G6LLU battery, 2100mAh.As I cannot see this listed in the TI Chemistry selection table I am attempting a chemistry selection test but without success so far....

View Article

Image may be NSFW.
Clik here to view.

usb interface adapter firmware update fail

Hi, everyoneI tried to update firmware at my interface adapter with the USB-TO-GPIO Firmware Loader. but it didnt work.(V1.2.2 -> V2.0.19 / I want to use BQ77910 EVM )  I checked that there are no...

View Article


NiMH Fuel Gauge

i am using a 14.4 V NiMH battery with 12 cells in series. I am wanting to implement a Fuel Gauge that would possibly communicate with a Stellaris (TIVA now i believe).I was wondering if anyone could...

View Article

bq34z110EVM: basic questions when used to monitor a string of 12V Lead-Acid...

Hello all,We will soon try the bq34z110EVM demo board and software, to have an overview of its capabilities when monitoring a string of 1 to 4 (or 3 apparantly due to a limitation in the demo board)...

View Article

Mathcad Chemistry Selection Tool (Rev. BP)

I have downloaded the Mathcad Chemistry Selection Tool, file sluc138bp.zip, by clicking on the link in the bq27500-V130 product page but I cannot extract the contents due to 'file invalid' error.Could...

View Article