Quantcast
Channel: Power management forum - Recent Threads
Viewing all 35901 articles
Browse latest View live

BQ27500 - Capacity error when I download the chemistery table (0287 - LGC 18650 MG1 2900mA)

$
0
0

Hello,

I've got an "capacity error popup message" when I'm trying to upload the chemistery table 0287 (LGC 18650 MG1 2900mA) with the bq Evaluation Software (Rev 0.9.92) in the bQEasy menu.

Everithing is working well except this function. When I use another table, it works but this one not.

Does somebody know what would be the issue ?...and the solution ?

PS: the component is a BQ27500

Thank you in advance


bq27425-G2A / CC deadband

$
0
0

Hi All,

Please let me ask about CC deadband. I understand that bq27425-G2A does not accumulate charge or discharge current when the voltage across SRX and VSS is less than CC deadband. Then,

  • Does it mean that CC ADC is disable?
  • Does RemCap or SOC not change if very small current is flow continuously but the voltage across SRX and VSS is less than CC deadband?

Best Regards,

Sonoki / Japan Disty

BQ27742-g1 floating point converstion

$
0
0

I am trying to calibrate a battery pack that uses a BQ27742-g1 gas gauge IC.  In doing the current calibration in order to calculate the ccGain and ccDelta the numbers must be converted from floating point to a special type of floating point understood by the gas gauge.  I followed their flow chart in the sluuax0b.pdf document (Section A.11) and wrote some c code to convert the number.  My problem is that I am questioning my results and have no way to test the answer I receive to make sure it is correct.  The byte0, byte1, and byte2 numbers I am getting end up being negative numbers, which I don't think is correct.  Does anyone have any code that implements their algorithm that they would be willing to share?  Or some example conversions of floating point numbers that I can check to make sure my algorithm is working?

regout specifications of the bq76920

$
0
0

for the BQ76920, the datasheet specs the regout to be either 2.5v or 3.3v. is this determined by the specific part or by some configuration?

thanks

Todd

bq40z60EVM firmware update

$
0
0

Hello Thomas:  I am using the TI bq40z60EVM module with the latest released version of Battery Management Studio.  The firmware supplied with the EVM is 4600_0_12-bq40z60 while the Battery Management Studio only recognizes 4600_0_13-bq40z60.

Two questions:  How do I update the embedded firmware (I only see the interface for programming *.Senc and *.srec, not *.bqz)?  And where can I find the latest bq40z60 firmware?

Thank you very much.

Joe Stark

Simple battery management monitor for 12-13 Li-Ion battery

$
0
0

Hi.

Could you help me. 

I want to make simple battery management monitor for 12-13 Li-Ion battery. What is the simplest battery monitor IC to know for my task?. I only need 3 charge levels: full, 50%, and empty.

BQ27541-G1 firmware version different than expected - wrong IC or just fw version?

$
0
0

Hi,

I have 4 different "versions" of a gas gauge BQ27541-G1, and I'm having some problem with the firmware versions. One of them returns 0x0200, and I would like to know if that means it is a BQ27541-V200, or it can be indeed a G1, with an old firmware version. What will be the problems of writing a golden image made for the G1 version on the V200 (if it is indeed a V200)? I did write it thinking it was a G1, it didn't "brick" but I'm not sure it is working properly either.

Is it possible to find the firmware version it was shipped with(or actual version of the device)? If yes, then the following codes are written over the ICs:

bq 7541 TI K 22GC

bq 7541 TITI 33NF

bq 7541 TIUK 31ND

bq 7541 TIUK 3161

att. Diogo Furukawa

Usb to GPIO adapter

$
0
0

Hello TI team,

I have problem to making firmware update for my USB to GPIO adapter  and me need help .... I tray with XP, win 7 32bit, win 7 64 bit , diferent PC , new software installation and not possible ?

Interface working but me need to exchange firmware to use for some software for battery calibration ...

I used  USB to gpio firware loader on XP , win 7 32 bit , 64 bit and not possible, every time I have error No adapter found  … or some error …

 

Please me nead step by step procedure I...  tray all … but not possible .

 

Regards

 

Zeca

 

zeca@eunet.rs

 

 


bq78pl116 resetting RSOC value

$
0
0

Dear all,

we use BQ78PL116 for a 1KWh battery pack with IP scale 10.

we have set the design capacity to the right "absolute capacity" (39Ah).

but the RSOC is immediately set to a value much higher.

I thought a few cycles would fix this but it just won't go down...

I can see that FC and FD flags are set and we are waiting enough time at idle current.

is there any way to set the value of the FCC ? it is now ~100Ah...

best regards,

BQ27421 Communication Freeze

$
0
0

Hello,

I'm using a BQ27421 in my design.

Sometimes the communication completly freeze until the battery is completly empty.

I didn't find any solution for this issue and it becomes critical.

Can you help me please?

The charging current is limited to 300mA, the max charging voltage is 4.2V.

Regards,


Guillaume Tiffineau

bq20z90 - is PFIN pulled up internally?

$
0
0

Hello, we need to know what happens if PFIN is floating on bq20z90, or more precisely, is there an internal pullup? (trying to avoid board spin)  The datasheet doesn't say one way or the other.

Thanks,

DelRae

BQ20Z65 Qmax not updating after 500 cycles

$
0
0

TI E2E Team,

I have a customer that is not getting a Qmax update on the BQ20Z65 after running through 500 cycles.  This is their direct response.  As well as their data collected and log, see attached.

"I can’t seem to get the fuel gauge to complete a Qmax update.

I have over 500 cycles and the % error has climbed to 23% and that indicates that no Qmax update has occurred.

The last few cycles I have done full charge and discharges with over 5 hours of rest at empty and full but no luck."

Any ideas as to why the it's not updating?  

Thanks!

 (Please visit the site to view this file)

BQ76930 - DEVICE_XREADY bit will not clear

$
0
0

I have designed and fabricated a BQ76930 AFE and BQ78350 GG pair:

  • Boards are configured to manage 6 Li-Ion cells
  • Proper shorting techniques were followed in BQ76930 datasheet to reduce cell count
  • During assembly, cells were connected in a bottom-up order starting with Pack-
  • External balancing FET circuitry

The AFE boots correctly and the BQ78350 can talk to it via I2C. BQ78350 functionality was verified over SMBus with BQStudio and an EV2400 board. BQ78350 is now being held in reset in order to not affect I2C bus. Currently am talking to AFE on I2C with the EV2400 board and the BQ76940 Evaluation Software:0.1.0.7.

The AFE is responsive. I can set and clear the ADC_EN and TEMP_S bits. The DEVICE_XREADY will not clear. Tried the 'Clear Faults' macro, tried writing 0xFF to address 0x00. All voltages and temperatures stay as zero. I2C integrity is fine and transactions are being verified on a scope. Have tried both the BQ7693000 and the BQ7693001. Both result in a frozen DEVICE_XREADY bit. This is the only bit set in the System Status register.

  • RGSRC =      9.08V
  • CAP1 =          3.29V
  • CAP2 =        10.66V
  • REGOUT =    2.52V
  • BAT =           21.55V
  • VC10 =        21.55V
  • VC[9,8,7] =  17.96V
  • VC6 =           14.36V
  • VC5B =        10.66V
  • VC5=            10.76V
  • VC5x=          10.66V
  • VC[4,3,2] =    7.18V
  • VC1 =             3.59V
  • VC0 =             0.00V

I looked at the AFE FAQ for an answer, but as far as I can tell, I am not violating any design rules. I can't see any reason that these should boot into this mode. Does anyone have any suggestions for troubleshooting?

bq34z110 : X10 mode setting

$
0
0

Hello!

I want to set the bq34z110 using X10mode.

But I can not understand exactly x10mode.

I test and that specifications are as follows:

1) Battery : 12V/55AH 1EA

2) Load : about 1A resistor 1EA

When X10 mode and set to "Design Energy Scale" to "10", all in DataFlash "mA, mAh, mW and mWh unit" do I need to set divided by "10"?

BQ34Z100 & BQ29200 Cell Balancinge Effect on SOH and SOC

$
0
0

Hello


We have a design using the BQ34Z100 and a BQ29200 overvoltage protector with in built cell balancing.

The cells are arranged as 2 in series.

As I understand it the balancing circuit shunts the cell with the highest voltage via some resistors untill the cells are balanced, this current will not be seen by the BQ34Z100. I assume that the voltage will adjust though, which will be seen by the gauge.

This balancing technique seems to be common, how will it effect the IT algorithms estimation of SOC and SOH?

Is it not a big issue?

I assume if the cells need serious ammounts of balancing the SOH is pretty low anyway.

Thanks

Morgan


bq40z50: FD, FC, TD, TC voltage thresholds

$
0
0

How do I go about determining the 8 voltage thresholds for FD, FC, TD, and TC?

Thanks.

Tom

Fuel Gauge bq20Z655 Chemistry File.

$
0
0

We are using a bq20z655 fuel gauge to support  Panasonic cells NCR1865F with a capacity of 2900 mAh. Using bqEasy Evaluation Software I first loaded Chemistry file 238 which returned an error message Unsupported Device Contact Battery Management Applications for assistance. Next I loaded file 281 which also supports this cell but I received the same error message. What should we try next?

Thank You

Mel Hall

CRTES

Any 1S Li-Ion gauge able to distinguish between >500 uA = NORMAL current and

$
0
0

Hello,

Are there any single cell gauges capable of distinguishing between > 500 uA for NORMAL current and <50 uA for SLEEP current?

I have a very small (< 75 mAh) battery. Gauges like bq27621-G1 and bq27421-G1 seem like a good fit, except it appears that the Sleep Current for these cannot be below 1 mA. In this use case, the system spends a lot of time in an 'idle mode' that draws between 0.5 and 1.5 mA, and I'd like to keep the gauge active in this state to keep the state-of-charge as accurate as possible.

From bq27421-G1 TRM p30:

Thanks,

Jonathan

Need a BQ3060 .senc File with Chemistry ID 404 (0x194)

$
0
0

In order to have initial readings for my LiFePO4 batteries that are more accurate than the initial readings provided by Chemistry ID (0x100), would it be possible to obtain a Factory .senc file with a chemistry ID of 404(0x194) loaded.

Thanks,

Rayn

what are the changes wrt to driver for BQ27425-G2A

$
0
0

Hi,

Please let me know what are the changes required for BQ274250G2A.

Regards,

Pranav

Viewing all 35901 articles