Part Number:LMR62014
Hi Team,
One of my customers is using LMR62014 to make 16V from 5V in energy meter application.The load is around 100mA for 20-50msec.
He is presently using 220pf as feedforward capacitor but is failing in radiated emission test .
If the value of Cff is increased from 220pf to 440pf the radiated emission result passes.
As the PCB is freezed The layout can not be changed.
There are two queries:
1. How feedforward capacitor is resulting in less Radiated emissions?
2. Is it ok to use 440pF in the design?What implications it can have?
Regards,